Color Control GX: v1.21 Firmware released

Firmware version v1.21 for the Color Control GX has now been released.
ChangelogThe changelog from v1.20 to v1.21 is:
VE.Bus systems with units running in parallel: in single phase installation (2 or more units), split-phase (4 or more units) and three phase (6 or more units).
Description:The reported Power (W) and Energy readings (kWh) are wrong while connected to the AC input, for example during charge and pass-through operation. The bug was in the VE.Bus firmware, and has been fixed in VE.Bus firmware version xxxx159, xxxx209, xxxx306. That firmware was released on February 17th.
CCGX version v1.21 and newer work around this bug by checking the VE.Bus firmware version when it detects a parallel system. When the VE.Bus firmware version contains the fix for the Power and Energy readings, it does nothing special. When it detects an older VE.Bus firmware, it activates a work around:
1) It uses the real power from each phase-master, and multiplies that with the number of slaves.
2) It no longer reports kWh readings for the VRM solar yield and consumption tab.
Recovery imagev1.21: http://www.victronenergy.com/feeds/ccgx/images/CCGX-v1_21-recover.zipJohn RushworthPrecisa de aconselhamento? Os nossos distribuidores altamente treinados têm todo o gosto em ajudar com qualquer questão, grande ou pequena.
Encontre um revendedor perto de si
Consulte os nossos recursos de suporte ou contacte o seu distribuidor original para assistência dedicada, reparações ou pedidos de garantia.
Suporte
Leia mais sobre a nossa garantia padrão de 5 anos, líder do setor, e o serviço global de reparação.
Garantia


Política de privacidade
Preferências de cookies
Utilização de cookies
Condições de utilização
Aviso legal
©Victron Energy 2026